Software Version
- KX-NCP500 / 1000 PBMPR Version 6.0
- KX-TDE100 / 200 PMMPR Version 6.0
- KX-TDE600 PGMPR Version 6.0
System Capacity
This Installation Manual is designed to serve as an overall technical reference for the Panasonic Pure IP-PBX, KX-NCP500/KX-NCP1000. It provides instructions for installing the hardware, and programming the PBX using the Maintenance Console. The Structure of this Manual. This manual contains the following sections: Section 1 System Outline. Page 14 Introduction Introduction This Installation Manual is designed to serve as an overall technical reference for the Panasonic Pure IP-PBX, KX-NCP500/KX-NCP1000. It provides instructions for installing the hardware, and programming the PBX using the Maintenance Console. The Structure of this Manual. Page 15: Table Of Contents. Page 13 Introduction Introduction This Installation Manual is designed to serve as an overall technical reference for the Panasonic Pure IP-PBX, KX-NCP500/KX-NCP1000. It provides instructions for installing the hardware, and programming the PBX using the Maintenance Console. The Structure of this Manual.
Maximum Number of Trunks and Extensions
The PBX supports the following number of trunks and extensions.
KX-NCP Series
Type | KX-NCP500 / KX-NCP1000 |
Total Number of Trunks | 128 |
---|---|
Trunk (Physical Trunk Card) | 64 |
Trunk (Virtual Trunk Card) | 64 |
H.323 Trunks | 32 |
SIP Trunks | 64 |
Total Number of Extensions | 172 |
Extension (Physical Extension Card) | 44 |
Extension (Virtual Extension Card) | 128 |
IP-PT and IP Software Phone | 128 |
SIP Phone | 128 |
Scroll
KX-TDE Series
Panasonic Kx Ncp500 Maintenance Console Download Windows 7
Type | KX-TDE100 | KX-TDE200 | KX-TDE600 | |||
Basic System | 2-shelf System | 3-shelf System | 4-shelf System | |||
Total Number of Trunks | 128 | 128 | 224 | 384 | 544 | 640 |
---|---|---|---|---|---|---|
Trunk (Physical Trunk Card) | 120 | 128 | 160 | 320 | 480 | 640 |
Trunk (Virtual Trunk Card) | 64 | 64 | 64 | 64 | 64 | 64 |
H.323 trunks | 32 | 32 | 32 | 32 | 32 | 32 |
SIP trunks | 64 | 64 | 64 | 64 | 64 | 64 |
Total Number of Extensions | 256 | 256 | 432 | 736 | 1008 | 1152 |
Extension (Physical Extension Card) | 160 | 256 | 304 | 608 | 880 | 1120 |
Extension (Virtual Extension Card) | 128 | 128 | 128 | 128 | 128 | 128 |
IP-PT and IP Software Phone | 128 | 128 | 128 | 128 | 128 | 128 |
SIP Extension | 128 | 128 | 128 | 128 | 128 | 128 |
Scroll
* The maximum number of PTs in the whole system is limited to 640.
Maximum Terminal Equipment
The following shows the number of each terminal equipment type supported by the PBX.
KX-NCP Series
Terminal Equipment Type | KX-NCP1000 |
Telephone | 172 |
---|---|
SLT | 36 |
KX-DT300 / KX-T7600 series DPT | 40 |
Other DPT | 10 |
APT | 4 |
IP-PT*1 | 128*2 |
SIP Extension | 128 |
DSS console | 8 |
CS | 21*3 |
PT-interface CS (2-channel) | 11 |
PT-interface CS (8-channel) | 5 |
IP-CS (8-channel) | 16 |
PS | 64 |
Voice Processing System (VPS) | 2 |
Doorphone | 16*4 |
Door Opener | 16 |
External Sensor | 16 |
External Relay | 16 |
Scroll
*1 KX-NT400, KX-NT300 series, and KX-NT265 (software version 2.00 or later only)
*2 For the KX-NT400, the maximum number of extensions that can be connected to the PBX is 64.
*3 One 8-channel PT-interface CS or IP-CS counts as 2 CSs, up to a maximum of 32 CSs. Therefore, the maximum number of CSs is 21 (eleven 2-channel CSs + ten 8-channel CSs).
*4 For the KX-NCP500, when using the DPH2 card, the maximum number of doorphones is 12.
KX-TDE Series
Terminal Equipment Type | KX-TDE100 | KX-TDE200 | KX-TDE600 | |||
Basic System | 2-shelf System | 3-shelf System | 4-shelf System | |||
Telephone (using Digital XDP) | 256 | 256 | 368 (432)*1 | 608 (736)*1 | 848 (1008)*1 | 992 (1152)*1 |
---|---|---|---|---|---|---|
SLT | 128 | 168 | 240 | 480 | 720 | 960 |
KX-DT300 / KX-T7600 series DPT | 128 | 256 | 256 | 512 | 640 | 640 |
Other DPT | 32 | 128 | 128 | 256 | 384 | 512 |
APT | 24 | 64 | 80 | 160 | 240 | 320 |
IP-PT | 192 | 192 | 288 | 448 | 608 | 704 |
IP-PT*2 (supported by IP-EXT16 card) | 96 | 128 | 160 | 320 | 480 | 640 |
IP-PT*3 (supported by IPCEMPR card) | 128*4 | 128*4 | 128*4 | 128*4 | 128*4 | 128*4 |
SIP Extension | 128 | 128 | 128 | 128 | 128 | 128 |
DSS console | 8 | 8 | 64 | 64 | 64 | 64 |
CS | 32*5 | 32*5 | 32*5 | 64*5 | 96*5 | 128*5 |
PT interface CS (2-channel) / CS for CSIF card | 32 | 32 | 32 | 64 | 96 | 128 |
PT interface CS (8-channel) | 16 | 16 | 16 | 32 | 48 | 64 |
IP-CS (8-channel) | 16 | 16 | 16 | 16 | 16 | 16 |
PS | 128 | 128 | 512 | 512 | 512 | 512 |
Voice Processing System (VPS)*6 | 2 | 2 | 8 | 8 | 8 | 8 |
Doorphone | 16 | 16 | 16 | 32 | 48 | 64 |
Door Opener | 16 | 16 | 16 | 32 | 48 | 64 |
External Sensor | 16 | 16 | 16 | 32 | 48 | 64 |
External Relay | 16 | 16 | 16 | 32 | 48 | 64 |
Panasonic Kx Nt346 User Manual
Scroll
Panasonic Kx Ncp500 Manual
*1 Even when Digital XDP is used, each shelf supports a maximum of 256 KX-DT300 / KX-t7600 series DPTs.
*2 KX-NT300 series (except KX-NT366/KX-NT305), KX-NT265, and KX-NT136.
*3 KX-NT400, KX-NT300 series, and KX-NT265 (software version 2.00 or later only).
*4 For the KX-NT400, the maximum number of extensions that can be connected to the PBX is 64.
*5 One 8-channel PT-interface CS or IP-CS counts as 2 CSs for the total number of CSs.